INITIALIZATION

FORCED INITIALIZATION WITH EXTERNAL LINE

Turn off the product, shortcircuit between the green line and
the orange line with white stripes, and turn it back on.

When the initialization is completed, 3 LED indicators are
blinking with a beep.

Restore the connection of the two lines back to their original
state.

HARDWARE FORCIBLE INITIALIZATION

This is to initialize the product forcibly by disassembling it.

Use this method only if you have lost the Master Card or the password, or if the forcible initialization with the external line
failed.

Turn off the product and detach it from the installation site, then loosen the screw (x4) on each corner to
disassemble it as shown.

Apply power to the product and short-circuit the jumper for
one second as shown.

When the initialization is completed, 3 LED indicators are
blinking.