SMC Networks ROBO Cylinder RGD4D User Manual

Page 48

Advertising
background image

38


14.5.5 Replacing the Belt of the Motor Reversing Type: RA4R Type


[Items Required for Replacement]
• Replacement

belt

RA4R --- 60S2M152R Rubber, cleanroom type (Bando Chemical Industries) 6 mm wide

• Allen

wrenches

• Tension gauge (capable of tensioning to 7 kgf or greater)
• Strong string, looped (or long tie-band)
• Scale

• Oil-based marker pen
• PC or teaching pendant


[Overview of Replacement]
1) Move the rod to a position where Z phase turns on (home position) (2 mm from the mechanical end). In

this position, loosen the motor-unit affixing bolts and replace the belt.

2) Restore the home position.

Affix the rod at a position 2 mm from the mechanical end on the home side, pass the belt, and adjust
the belt to the specified tension.

3) Perform homing using a PC or teaching pendant and check for deviation from the initial home position.

If there is a deviation, adjust the home offset if you are using an SCON controller. If you are using an
SSEL or X-SEL controller, adjust the home preset.



















Home position

Z phase ON
position

Mechanical end

Approx. 2 mm

The countermark on the motor
aligns with this position.

Set by the home offset parameter (SCON) or home preset parameter
(SSEL, X-SEL). (The above value indicates the factory setting.)

1 mm

Advertising