LS 1000 Product Reference Guide: Chapter 3, Maintenance and Specifications

Table 3-2. Technical Specifications (LS 1004)

Item

Description

Power Requirements*

RS-232C/Synapse
Low Power

4.75 to 14.5 VDC (max) 100mA @ 5VDC typical
4.75 to 14 VDC (max) 200 mA @ 5V typical

Decode Capability

The LS 100x can be programmed to decode the
following code types: UPC/EAN, Code 39,
Code 39 Full ASCII, Code 93, Codabar,
Interleaved 2 of 5, Code 128, EAN 128, and
Discrete 2 of 5. Set code length(s) for any linear
code type. The LS 100x can auto-discriminate
between all of the above code types except for
Code 39 and Code 39 Full ASCII.

Beeper Operation

User-selectable: Enabled, Disabled., Volume, Tone

Scan Repetition Rate

36 (± 3) scans/sec (bidirectional)

Skew Tolerance

± 65˚ from normal

Pitch

± 60˚ from normal

Decode Depth of Field

See Decode Zone

Print Contrast Minimum

25% absolute dark/light differential, measured at
670 nm.

Ambient Light Immunity

Artificial Lighting
Sunlight

450 ft. candles 4844 lux
8000 ft. candles86112 lux