DIMENSIONS AND SPECIFICATIONS

Clearances

Clearances Applicable For All Models

Surface

Sides

Rear

Combustible Wall Minimum

12” (305mm)

6” (152mm)

Non-Combustible Wall Minimum

0”

0”

Gas Pressures

Gas

Minimum Supply

Pressure

Manifold Operating

Pressure

Natural

7” WC (17 .5 mbar)

4 .5” WC (11 .25 mbar)

Propane

11” WC (28 mbar)

10” WC (25 mbar)

Gas Inlet Size

Model Width

Connection

24” (610mm) &

36” (914mm)

3/4” NPT

Rear Gas Connection

60” (1524mm)

1” NPT

Rear Gas Connection

Individual Burner Input Rates

Burner

Input BTU/HR

Natural

Gas

Propane

Gas

Open Top

30,000

26,000

Hot Top Burner (In lieu of 2 open top burners)

20,000

19,000

Griddle Burner (In lieu of 2 open top burners)

20,000

19,000

Raised Griddle Broiler (Consists of 3 burners)

33,000

33,000

Oven Burner Standard

33,000

29,000

Space Saver Oven

25,000

25,000

Rates are for installations up to 2000’ (610m) above sea level