MAINTENANCE AND TROUBLESHOOTING

There is a small red ×
on the SMART Board
icon .

(continued)

The camera calibration
data is lost.

Restore the back-up camera data
from the registry.

To restore the back-up camera
data:

1. In the Windows notification

area, select the SMART
Board
icon , and then select
Control Panel.

The SMART Notebook control
panel opens.

2. Select About Software and

Product Support > Tools >
Diagnostics.

The SMART Board
Diagnostics
window opens.

3. Select Default (or Restore

Camera Defaults) to restore
the camera data.

4. Close the SMART Board

Diagnostics window, and then
close the SMART Notebook
control panel.

NOTE
The Connection Wizard
enables the Restore Camera
Defaults
button if both
cameras are detected but
your interactive whiteboard
isn’t detected.

Symptoms

Cause

Solution