Planning Information

11

Plumbing Requirements.

All built-in models with an

automatic ice maker come with a microbiological water

filtration system. The water supply line should be located

within the shaded area shown in the illustration. The

water supply line should be connected to the house

supply with an easily accessible shut-off valve between

the supply and the unit. Do not use self-piercing valves.

A saddle valve kit (4200880) is available from your

Sub-Zero dealer. The water line must not interfere with

installation of the anti-tip brackets.

IMPORTANT NOTE:

A reverse osmosis system can be

used provided there is constant water pressure of 30 psi

(2.1 bar) to 100 psi (6.9 bar) supplied to the unit at all

times. In this application, the microbiological water filtra-

tion system should be set to bypass mode by removing

the water filter cartridge and inserting the bypass plug

(7005018) available from your Sub-Zero dealer. Installation

instructions packed with the unit will outline this

procedure.

Plumbing Requirements

Water Supply Line

1

/

4

" OD copper line

Water Pressure

30–100 psi

(2.1–6.9 bar)

Excess Water Line for Connection

36"

(914)

1

/

2

"

(13)

18"

(457)

6"

(152)

SHUT-OFF

VALVE

WATER LINE

18"

(457)

W

6"

(152)

3"

(76)

FRONT VIEW

TOP VIEW

Location of water supply.

subzerotrade.com