Dual installations, Dual standard installations – Sub-Zero 601RG User Manual

Page 30

Advertising
background image

Dual Installations

30

Dual Standard Installations.

Two framed, overlay

or stainless steel units may be placed side by side in a

dual installation. Some dual standard installations will

require a dual installation kit, available through your

Sub-Zero dealer. If you are installing two units side by

side in a flush inset application refer to page 33.

A custom filler strip can be used in between two units in a

framed, overlay or stainless steel design application. It is

recommended that the filler strip be at least 2" (51) wide,

to prevent condensation between the units. Be sure to

add the filler strip width to your rough opening width.

Refer to the full-scale template on page 41.

Dual installations without a filler strip can only be accom-

plished using two units with opposite hinges as shown in

illustration A below. The dual installations shown in illus-

trations B and C require a filler strip.

IMPORTANT NOTE:

For the application shown in illustra-

tion A, a dual installation accessory kit is required. Refer

to page 36 for information on dual installation accessory

kits.

Dual Standard Installation

Dual Installation Panel Requirements

MAX WEIGHT PER PANEL

BI-36R, BI-36RG and BI-36F

75 lbs

(34 kg)

All Other Models

50 lbs

(23 kg)

Dual Wide Grille Panel

26 lbs

(12 kg)

MIN PANEL THICKNESS

Framed Panels

1

/

4

"

(6)

Overlay and Flush Inset Panels

5

/

8

"

(16)

Illus. A

WITHOUT FILLER STRIP

FILLER STRIP REQUIRED

FILLER STRIP REQUIRED

Illus. B

Illus. C

Dual

Installations