Framed panels – Sub-Zero 601RG User Manual

Page 13

Advertising
background image

Framed Panels

13

Framed Panels.

If the thickness of the custom panels

is less than

1

/

4

" (6), they must be backed up with a sheet

of shim material to build the total thickness to

1

/

4

" (6). If

the panel is thicker than

1

/

4

" (6), a routed edge must be

provided around the panel to ensure a proper fit. Refer to

the illustrations.

IMPORTANT NOTE:

On all framed models, routing,

recessing or optional extended handles may be required

on raised panels for finger clearance under the handle.

Refer to the full-scale templates at the end of this guide.

IMPORTANT NOTE:

On glass door models, the edges of

the window cut-out will need to be finished, as they will

be exposed.

IMPORTANT NOTE:

When installing two units in a side by

side application, refer to pages 30–31 for dual standard

installations. Be aware that rough opening dimensions are

different for this application.

1

/

4

"

(6)

PANEL

TRIM
REVEAL

1

/

4

"

(6) min

DOOR

MAIN FRAME

Panels

1

/

4

" (6) thick or less.

Panels thicker than

1

/

4

" (6).

TRIM
REVEAL

1

/

4

"

(6) min

ROUT TO

1

/

4

"

(6)

DOOR

MAIN FRAME

Do not exceed the framed decorative panel dimen-

sions. Exceeding dimensions could cause damage

to the panels and the Sub-Zero unit.

Framed

subzerotrade.com

Advertising
This manual is related to the following products: