Resetting the lamp timer – Sharp Notevision PG-C355W User Manual

Page 65

Advertising
background image

-63

Appendix

User service screw
(for lamp unit cover)

AC socket

5

Insert the new lamp unit.

• Press the lamp unit firmly into the lamp

unit compartment. Fasten the securing
screws.

6

Replace the lamp unit cover.

• Align the lamp unit cover and slide it to

close. Then tighten the user service
screw to secure the lamp unit cover.

Info

• If the lamp unit and lamp unit cover are not

correctly installed, the power will not turn
on, even if the power cord is connected to
the projector.

Resetting the Lamp Timer

Reset the lamp timer after replacing the lamp.

Info

• Make sure to reset the lamp timer only

when replacing the lamp. If you reset the
lamp timer and continue to use the same
lamp, this may cause the lamp to become
damaged or explode.

• You can also reset the lamp timer via the

LAN.
(Refer to the SETUP MANUAL on the sup-
plied CD-ROM for details.)

1

Connect the power cord.

• Plug the power cord into the AC socket

of the projector.

2

Reset the lamp timer.

• While simultaneously holding down ",

ENTER and MENU on the projector,
press STANDBY/ON on the projector and
keep all four buttons pressed down until
the lamp indicator starts blinking green.

• “LAMP 0000H” is displayed, indicating

that the lamp timer is reset.

" button

ENTER button

STANDBY/ON button

Lamp indicator

MENU button