Common system messages, Maintenance, That – Sierra Housewares S5012 User Manual

Page 50

Advertising
background image

46

6

Maintenance

Common System Messages

Below is an explanation of the common messages your keypad
might display. Beside each message is a discussion of what re-
sponses are appropriate. If you find the response is ineffective,
call your local C&K service representative.

In the table below, the ellipses (...) represent the specific informa-
tion, such as zone numbers, that follows the system message.

If you notice

That means

What to do:

Power LED is off

The system is not

Verify that the rest of the

receiving AC (house

building is receiving power;

current) power

then call for service.

That

Display reads:

A zone is faulted;

Correct the fault (by

"Faulted..."

cannot fully arm

closing doors/windows); or
bypass the zone.

Display reads:

A sensor needs

Bypass the sensor, or

"Trouble..."

service

arrange for repair.

Display reads:

A sensor may have

Call for service.

"Tamper..."

been tampered with

Display repeatedly

A sensor may need

Call for service.

reads: "Trouble..."

service

"Tamper..."

Display reads:

Any one of your

Depending upon your

Ready"

sensors may be

arming type, your system

faulted

may be able to arm. If not,
correct any faulted zones,
then attempt to arm.

Display reads

An alarm occurred

Refer to "Resetting After an

"Alarm..."

Alarm" in Section 4.

Display reads

A zone has been

Remember the zone is

"Bypass..."

bypassed

unprotected while bypassed.
You can remove the bypass
(see Section 3), or arm/
disarm with bypass in place.

Advertising
This manual is related to the following products: