5 scsi bus timing – Seagate Ultra 320 User Manual

Page 34

Advertising
background image

20

Parallel SCSI Interface Product Manual, Rev. A )

2.5

SCSI bus timing

Unless otherwise indicated, the delay time measurements for each SCSI device, defined in paragraphs 2.5.1
through 2.5.60 shall be calculated from signal conditions existing at that SCSI device’s own SCSI bus connec-
tion. Thus, these measurements (except skew delay) can be made without considering delays in the cable.
Refer to the tables below for the actual timing values for these delays.

Table 4:

SCSI bus control timing values in nanoseconds

[1]

Cable skew is measured at each SCSI device connection with the transmitted skew subtracted from the
received skew.

[2]

This is a recommended time. It is not mandatory.

Timing description

Reference

Type

Timing

value (ns

unless

noted)

Arbitration delay

2.5.1

minimum

2.4 µs

Bus clear delay

2.5.4

maximum

800

Bus free delay

2.5.5

minimum

800

Bus set delay

2.5.6

maximum

1.6 µs

Bus settle delay

2.5.7

minimum

400

Cable skew

[1]

2.5.8

maximum

4

Data release delay

2.5.21

maximum

400

DIFFSENS voltage filter time

2.5.22

minimum

100 ms

Physical disconnection delay

2.5.24

minimum

200 µs

Power on to selection

[2]

2.5.25

maximum

10 s

QAS arbitration delay

2.5.26

minimum

1000

QAS assertion delay

2.5.27

maximum

200

QAS release delay

2.5.28

maximum

200

QAS non-data phase REQ(ACK) period

2.5.29

minimum

50

Reset delay

2.5.42

minimum

200

Reset hold time

2.5.43

minimum

25 µs

Reset to selection

[2]

2.5.44

maximum

250 ms

Selection abort time

2.5.46

maximum

200 µs

Selection time-out delay

[2]

2.5.47

minimum

250 ms

System deskew delay

2.5.51

minimum

45

Advertising