Wire serial interface hardware design, Application, 5-wire serial interface hardware design – Sierra Wireless AIRPRIME WISMO218 User Manual

Page 38: 4-wire serial interface hardware design, 2-wire serial interface hardware design

Advertising
background image

WA_DEV_W218_PTS_002

Rev 006

April 29, 2010

38

Product Technical Specification &
Customer Design Guidelines

Interfaces

3.6.2.1.

5-wire Serial Interface Hardware Design

 Signal: CT103/TXD*, CT104/RXD*, ~CT105/RTS*, ~CT106/CTS*
 The signal ~CT108/DTR* must be managed following the V24 protocol signaling if we want to

use idle mode.

 For detailed configuration, please refer to Figure 10 Example of V24/CMOS Serial Link

Implementation for 5-wire UART.

3.6.2.2.

4-wire Serial Interface Hardware Design

 Signal: CT103/TXD*, CT104/RXD*, ~CT105/RTS*, ~CT106/CTS*
 The signal ~CT108/DTR* can be looped back to ~CT107/DSR from both the AirPrime

WISMO218 side and from the DTE side.

 For detailed configuration, please refer to Figure 9 Example of V24/CMOS Serial Link

Implementation for 4-wire UART.

3.6.2.3.

2-wire Serial Interface Hardware Design

 This case is possible for a connected external chip, but it is not recommended.
 The flow control mechanism has to be managed from the customer side.
 Signal: CT103/TXD*, CT104/RXD*
 The signal ~CT108/DTR* can be looped back to ~CT107/DSR from both the AirPrime

WISMO218 side and from the DTE side.

 The signals ~CT105/RTS*, ~CT106/CTS* are not used, please configure using the AT

command, AT + IFC = 0,0 (see document [2] AirPrime WISMO218 AT Commands Manual).

 The signal ~CT105/RTS* can be looped back to ~CT106/CTS* from both the AirPrime

WISMO218 side and from the DTE side.

 For detailed configuration, please refer to Figure 8 Example of V24/CMOS Serial Link

Implementation for 2-wire UART.

Note:

The loop back connection of ~CT108/DTR* to ~CT107/DSR is not allowed when the case
AT+PSSLEEP=0 is used, for which sleep mode entry is ~CT108/DTR* level dependent. (Refer to
Note 1 of the Power Consumption
section. In order to go to sleep mode properly under such
configuration, AT+PSSLEEP=1 should be used instead. For details, please refer to document [2]
AirPrime WISMO218 AT Commands Manual.

*

According to PC (DTE) view

3.6.3.

Application

The level shifter must be a V28 electrical signal compliant with 2.8V.

Advertising