On/~off signal, Features, Pin description – Sierra Wireless AIRPRIME WISMO218 User Manual

Page 63: Extra note, Table 25, Electrical characteristics of the on/~off signal, Table 26, On/~off signal pin descriptions

Advertising
background image

WA_DEV_W218_PTS_002

Rev 006

April 29, 2010

63

Product Technical Specification &
Customer Design Guidelines

Interfaces

3.13. ON/~OFF Signal

The ON/~OFF pin is used to switch ON or switch OFF the AirPrime WISMO218.

ON/~OFF signal is internally connected to the permanent 3.0V supply regulator inside the AirPrime
WISMO218 via a pull-up resistor. Once there is VBATT supply to the AirPrime WISMO218, this 3.0V
supply regulator will be enabled and so the ON/~OFF signal is by default at HIGH level.

A LOW level signal has to be provided on the ON/~OFF pin to switch ON the AirPrime WISMO218.

Caution: All external signals must be inactive when the AirPrime WISMO218 is OFF to avoid any damage

when starting and to allow the AirPrime WISMO218 to start and stop correctly.

Avoid using application MCU GPIO to directly control the ON/~OFF signal of the AirPrime
WISMO218; instead, control this signal via an open collector switching transistor.

3.13.1. Features

Table 25: Electrical Characteristics of the ON/~OFF Signal

Parameter

I/O Type

Minimum

Typ.

Maximum

Unit

V

IH

2V8

2.4

-

3.0

V

V

IL

2V8

-

-

0.4

V

3.13.2. Pin Description

Table 26: ON/~OFF Signal Pin Descriptions

Signal

Pin Number

I/O

I/O Type

Description

ON/~OFF

37

I

2V8

AirPrime WISMO218 Power ON/OFF

Advertising