Power off, Software power off, Hardware power off – Sierra Wireless AIRPRIME WISMO218 User Manual

Page 66: 5sec, Figure 32, Power-off sequence

Advertising
background image

WA_DEV_W218_PTS_002

Rev 006

April 29, 2010

66

Product Technical Specification &
Customer Design Guidelines

Interfaces

3.13.3.2. Power OFF

The AirPrime WISMO218 can be powered off by either software or hardware.

3.13.3.2.1.

Software Power OFF

AT command: AT+CPOF is used to power off the AirPrime WISMO218.

Caution: If the ON/~OFF pin is maintained at LOW level when AT+CPOF is used, the embedded module can’t

be switched OFF.

3.13.3.2.2.

Hardware Power OFF

A LOW level pulse is applied on the ON/~OFF pin for 5.5sec. AT+CPOF will then be automatically
sent to the AirPrime WISMO218.

Once the AirPrime WISMO218 receives the AT+CPOF command, the AirPrime WISMO218 will be
deregistered from the network. The WISMO_READY pin will become LOW to indicate that AT
commands are no longer available for the AirPrime WISMO218. If the ON/~OFF signal is HIGH, then
the AirPrime WISMO218 will also be switched off.

Figure 32.

Power-OFF Sequence

Advertising