Speaker features, Speakers outputs power, Spk outputs – Sierra Wireless AIRPRIME WISMO218 User Manual

Page 48: Table 17, Speaker details

Advertising
background image

WA_DEV_W218_PTS_002

Rev 006

April 29, 2010

48

Product Technical Specification &
Customer Design Guidelines

Interfaces

Parameters

Min

Typ

Max

Unit

Z2 MICP
(MICN=GND)

2.2

Z2 MICN
(MICP=GND)
Impedance between
MICP and MICN
without 2.2K

 to

GND

4.5

Impedance between
MICP and MICN with
2.2K

 to GND

3.2

Maximum working voltage
( MICP-MICN)
(THD 10%)


AT+VGT*=1

-

-


210

mVpp

Maximum rating voltage
(MICP or MICN)


-0.5


-


4.4

V

*

The input voltage depends on the input micro gain set by the AT command. Please refer to document [2],

AirPrime

WISMO218 AT Commands

Manual.

**

Because both MICP and MICN are internally biased, it is necessary to use a coupling capacitor to connect an

audio signal provided by an active generator. Only a passive microphone can be directly connected to the MICP input.

3.10.2. Speaker Features

The speaker, SPK, can either have a single-ended or a differential connection. However, it is strongly
recommended to use a differential connection in order to reject common mode noise and TDMA
noise. Moreover, in single-ended mode, half (1/2) of the power is lost.

When using a single-ended connection, be sure to have a very good ground plane, very good filtering
as well as shielding in order to avoid any disturbance on the audio path.

Table 17: Speaker Details

Parameter

Typ

Unit

Connection

Z (SPKP, SPKN)

16 or 32

Differential mode

Z (SPKP, SPKN)

8

Single-ended mode

3.10.2.1. Speakers Outputs Power

The maximal specifications given below are available with the maximum power output configuration
values set by an AT command. The typical values are recommended.

3.10.2.1.1.

SPK Outputs

The SPK interface allows for both differential and single ended speaker connections.

Advertising