Master reset, Final sea trial – Simrad AP25 User Manual

Page 134

Advertising
background image

Simrad AP25 Autopilot

132

20221495F

SimNet gateway
Indicates which control unit that
transmits and receives information
on SimNet. The display verifies by
reading ‘Yes’, all other units display
‘No’.
Global SimNet reset
Resets the entire SimNet setup in the
Simrad Group and initiates a new
automatic interface setup. See
chapter 4.1.

Master Reset

Note !

A Master Reset is part of the final test at the factory, which will
reset the memories to factory settings. Unless you need to clear
all stored values during the installation setup procedure, you
should not perform a Master Reset.

The Master Reset needs a double
confirmation to prevent an
accidental reset. To perform a
Master Reset, rotate the course
knob clockwise and observe the
display; then rotate the course
knob counter clockwise. The
display will then read: “Master
Reset confirmed”.

Unless you have made a Master Reset, exit the Installation Menu
by pressing STBY to return to normal AP25 operation.
In the event a Master Reset has been made, refer to chapter 4.2.

Final sea trial

After having completed all settings in the Installation Menu, take
the boat out and perform a final sea trial in open waters at a safe
distance from other traffic.
• Steer the boat on all cardinal headings in AUTO mode.
• Start with low and medium speeds to get familiar with the

response from the AP25.

Advertising