9 fu25 steering lever – Simrad AP25 User Manual

Page 158

Advertising
background image

Simrad AP25 Autopilot

156

20221495F

8.9

FU25 Steering Lever

Dimensions: ............................... See Figure 8-9

Handle can be mounted pointing upwards or downwards.

Weight: ...................................... 1.2 kg (2.6 lbs.) including cable
Material:..................................... Polyacetal (POM)
Environmental Protection:......... IP56
Power consumption: ................. 3W
Safe distance to compass:.......... 0.15 m (0.5 ft.)
Temperature:

Operating: ......................... –25 to +55°C (–13 to +130°F)
Storage: ............................. –30 to +70°C (–22 to +158°F)

Cable:......................................... 10 m (33 ft.) cable with three twisted pairs of

wire run through a cable gland.

(cable gland can alternatively be mounted on back cover; see Figure 8-9)

Max. rudder command angle:.... Equal to physical stop minus 2°
Autopilot interface:.................... Via proprietary Robnet2™ bus
Accuracy:................................... ±1° within ±40° of mid-position at 25°C

Figure 8-9 FU25 Steering Lever Dimensions