3.10 Drive unit installation

The relations between drive units, drive unit voltage, autopilot
computer, drive performance and interface to the steering gear
are shown in the tables below.
Refer to the connecting diagram for the different drive units on
page 74 onwards.
Installation instruction for the drive units are found in the
manual for the individual units.
The maximum drive current capability of the AC10, AC20 and
AC40 autopilot computers are different. Use the table below as
reference and observe the notes on next page.

HYDRAULIC PUMPS

RAM

CAPACITY

MODEL MOTOR

VOLTS

AUTOPILOT

COMPUTER

MIN

cm

3

(cu. in.)

MAX

cm

3

(cu. in.)

FLOW RATE

AT 10 bar

cm

3

/min

(cu. in/min)

MAX

PRESSURE

bar

PWR.

CONSUM-

PTION

RPU80 12V AC10 80

(4,9)

250

(15,2)

800 (49)

50

2,5-6 A

RPU160 12V

AC20 160

(9,8)

550

(33,5)

1600 (98)

60

3-10 A

RPU300 12V

AC40

290

(17,7)

960

(58,5)

3000 (183)

60

5-25 A

RPU300 24V

AC20

290

(17,7)

960

(58,5)

3000 (183)

60

2,5-12 A

Steering gear interface: Hydraulic plumbing
Notes !

1. The AP25 system detects whether a reversible motor or a

solenoid is connected and outputs the correct drive signal
automatically.

2. The drive output of AC10 is sufficient for any type of 12 and

24V solenoids normally found on a recreational boat.