Simrad AP25 User Manual

Page 80

Advertising
background image

Simrad AP25 Autopilot

78

20221495F

both ends are available in 1, 5 and 10 m length. For cable
extension a Robnet2 T-Joiner is required.
When installing a system, try to minimize total Robnet2 cable
length by connecting all Robnet2 units to the nearest available
Robnet2 connector.
Total length of Robnet2 cable installed in a system should not
exceed 50 m (165').
Examples of interconnecting Robnet2 units:

CONTROL

UNIT

CONTROL

UNIT

AP27

CONTROL

UNIT

COMPASS

AUTOPILOT
COMPUTER

JP27

Figure 3-9 Interconnecting Robnet2 units

A Robnet2 T-joiner P/N 24005662 is available to make the
Robnet2 interconnection more simple by reducing the number of
cables or extend cables when necessary.
See table for pin configuration and colour code of the network
cable.

Cable pairs Color code

Signal

Pink V

SYSTEM+

1. pair

Grey V

SYSTEM–

Brown Bus–

2. pair

White Bus+

Yellow

On - Off

Figure 3-10 Robnet2 Connector

Note !

The connectors are weather proof according to IP65, when
properly installed. All connectors not in use must be fitted with
the plastic cap to protect them against dirt and moisture.