4

D. Connect the power cord. The plug is designed for 115

volt/15 amp duty. The unit must be connected to a
properly grounded receptacle. The electrical cord fur-
nished as part of the freezer has a three prong ground-
ing type plug. The use of an extension cord is not
recommended. If one must be used, use one with a
size 12 gauge or heavier with a ground wire. Do not use
an adaptor to get around grounding requirements.

CAUTION

DO NOT ALTER OR DEFORM PLUG IN ANY WAY!

E. Install the drip tray, cover and other miscellaneous

parts on the freezer.

2.4 INSTALLING PERMANENT WIRING
If permanent wiring is required by local codes, the following
procedure must be performed.

WARNING

DISCONNECT FREEZER FROM THE SOURCE OF
ELECTRICAL SUPPLY BEFORE SERVICING.

A. Remove the necessary panels to gain access to the

power cord connection.

B. Disconnect the black and white wires from the terminal

block (L1 and common). Disconnect the green ground
wire from the grounding screw.

C. Remove the strain relief connector from the bottom of

the freezer base.Remove the power cord.

D. Install permanent wiring according to local code.
E. Connect black wire to L1 on the terminal block. Con-

nect the white wire to the common on the terminal
block. Connect the green or yellow and green striped
ground wire to the grounding screw.

F. Replace all panels.

Figure 4. Power Cord