Stoelting SC118 User Manual

Page 15

Advertising
background image

7

C. Lubricate the drive end of the agitator (rear) shaft with

a small amout of white socket lubricant. A small
container of socket lubrication is shipped with the
freezer.

D. Install the two plastic agitator blades onto the agitator.

Install front agitator bearing.

E. Push the auger into the freezer barrel and rotate slowly

until the agitator engages the drive.

F. Assemble and install the spigot body with "O" Rings

into the spout. Push straight in until the spigot is in
place. Then install the horse shoe clip.

G. Install door "O" Ring.

H. Install the front door on the freezer.

I. Install the knobs on the freezer studs and tighten.

CAUTION

FINGER TIGHTEN THE KNOBS EVENLY. DO NOT
OVER-TIGHTEN KNOBS.

Look for the poper seal between the freezer barrel door, "O"
Ring, and front door.

3.7 SANITIZING
Sanitizing must be done after the freezer is clean and just
before filling with mix. Sanitizing the night before is not
effective.
However, you should always clean the freezer
and parts after using it.

WARNING

THE UNITED STATES DEPARTMENT OF AGRI-
CULTURE AND FOOD AND DRUG ADMINISTRA-
TION REQUIRE THAT ALL CLEANING AND SANI-
TIZING SOLUTIONS USED WITH FOOD PRO-
CESSING EQUIPMENT BE CERTIFIED FOR THIS
USE. USE "STERA-SHEEN" OR EQUIVALENT.

When sanitizing the freezer, refer to local sanitary regula-
tions for applicable codes and recommended sanitizing
products and procedures. The frequency of sanitizing
must comply with local health regulations. Mix sanitizer
according to manufacturer's instructions to provide a 100
parts per million strength solution. Mix sanitizer in quan-
tities of no less than 2 gallons (7.5 liters) of 120°F water.
Allow sanitizer to contact the surfaces to be sanitized for
5 minutes. Any sanitizer must be used only in accordance
with the manufacturer's instructions.

NOTE

Stoelting, Inc. has found that STERA-SHEEN
GREEN LABEL SANITIZER AND CLEANER does
an effective job of properly sanitizing and cleaning a
soft serve freezer. We therefore include a sample
with each new freezer. For further information read
the directions on the packet. Other products may
be as effective.

3.4 CLEANING THE FREEZER PARTS
Place all loose parts in a pan or container and take to the
wash sink for cleaning. To clean freezer parts refer to the
following steps:

A. Place all parts in warm mild detergent water and clean

with brushes provided. Rinse all parts with clean hot
water.

CAUTION

DO NOT DAMAGE PARTS BY DROPPING OR
ROUGH HANDLING.

B. Wash the freezer barrel and spout with warm detergent

water and brushes provided.

C. The exterior should be kept clean at all times to

preserve the lustre of the stainless steel. A mild alkaline
cleaner is recommended. Use a soft cloth or sponge to
apply the cleaner.

D. Remove the drip tray and insert. Clean with a soap

solution. Rinse with clean hot water.

3.5 SANITIZE FREEZER AND FREEZER PARTS

A. Use a sanitizer mixed according to manufacturer's

instructions to provide a 100 parts per million strength
solution. Mix sanitizer in quantities of no less than 2
gallons (7.5 liters) of 120°F water. Allow the sanitizer to
contact the surfaces to be sanitized for 5 minutes. Any
sanitizer must be used only in accordance with the
manufacturer's instructions.

B. Place all parts in the sanitizing solution, then remove

and let air dry.

3.6 ASSEMBLY OF FREEZER
To assemble the freezer parts, refer to the following steps:

NOTE

Petro-Gel sanitary lubricant or equivalent must be
used when lubrication of parts is specified.

NOTE

The United States Department of Agriculture and
the Food and Drug Administration require that lubri-
cants used on food processing equipment be certi-
fied for this use. Use lubricants only in accordance
with the manufacturer's instructions.

A. Assemble all "O" Rings onto parts dry, without lubrica

tion. Then apply a thin film of sanitary lubrication to
exposed surfaces of the "O" Rings. Apply a thin film of
sanitary lubricant on the fron tof the agitator shaft.

B. Assembly the rear seal assembly onto the agitator. Be

sure the "O" Rings and gaskets are in place before
installing the rear seal.