Making a Serial Connection to the SP

To make a serial connection to the SP:

1. Connect a serial cable from the RJ-45 Serial Management port on server to a

terminal device.

2. Press ENTER on the terminal device to establish a connection between that

terminal device and the ILOM SP.

Note –

If you are connecting to the serial port on the SP before it has been powered

up or during its power-up sequence, you will see boot messages.

The service processor eventually displays a login prompt. For example:

SUNSP0003BA84D777 login:

The first string in the prompt is the default host name for the ILOM SP. It consists
of the prefix SUNSP and the MAC address of the ILOM SP. The MAC address for
each ILOM SP is unique.

3. Log in to the SP and type the default user name, root, with the default

password, changeme.

Once you have successfully logged in to the SP, it displays its default command
prompt.

->

4. To start the serial console, type the following commands:

cd /SP/console

start

To exit console mode and return to the service processor, type
(escape/shift 9)

Continue with the following procedures:

“Viewing ILOM SP Event Logs” on page 45

“Viewing Replaceable Component Information” on page 48

“Viewing Sensors” on page 50