Sun Fire X4140, X4240, and X4440 Servers Diagnostics Guide • August 2008

PCI SERR,
PERR

System or parity
error on a PCI bus.

Sync floods on HyperTransport links, the
machine resets itself, and error information
gets retained through reset.
The BIOS reports, A Hyper Transport
sync flood error occurred on last

boot, press F1 to continue

.

DMI Log
SP SEL

Fatal

BIOS POST
Microcode
Error

The BIOS could not
find or load the
CPU Microcode
Update to the CPU.
The message most
likely appears when
a new CPU is
installed in a
motherboard with
an outdated BIOS.
In this case, the
BIOS must be
updated.

The BIOS displays an error message, logs the
error to DMI, and boots.

DMI Log

Non-fatal

BIOS POST
CMOS
Checksum Bad

CMOS contents
failed the
Checksum check.

The BIOS displays an error message, logs the
error to DMI, and boots.

DMI Log

Non-fatal

Unsupported
CPU
configuration

The BIOS supports
mismatched
frequency and
steppings in CPU
configuration, but
some CPUs might
not be supported.

The BIOS displays an error message, logs the
error, and halts the system.

DMI Log

Fatal

Correctable
error

The CPU detects a
variety of
correctable errors in
the MCi_STATUS
registers.

The CPU corrects the error in hardware. No
interrupt or machine check is generated by
the hardware. The polling is triggered every
half second by SMI timer interrupts, and is
done by the BIOS SMI handler.
The SMI handler logs a message to the SP
SEL if the SEL is available, otherwise SMI
logs a message to DMI. The BIOS's polling
can be disabled through software SMI.

DMI Log
SP SEL

Normal
operation

Single fan
failure

Fan failure is
detected by reading
tach signals.

The Front Fan Fault, Service Action Required,
and individual fan module LEDs are lit.

SP SEL

Non-fatal

TABLE D-1

Hardware Error Handling Summary (Continued)

Error

Description

Handling

Logged (DMI
Log or SP
SEL)

Fatal?