Bios dimm error messages, Dimm fault leds – Sun Microsystems Sun Fire X4240 User Manual

Page 25

Advertising
background image

Chapter 3

Troubleshooting DIMM Problems

15

to view ECC errors

Linux:

The HERD utility can be used to manage DIMM errors in Linux. See the x64
Servers Utilities Reference Manual
for details.

If HERD is installed, it copies messages from /dev/mcelog to
/var/log/messages

.

If HERD is not installed, a program called mcelog copies messages from
/dev/mcelog to /var/log/mcelog

.

The Bootable Diagnostics CD described in

Chapter 2

also captures and logs CEs.

BIOS DIMM Error Messages

The BIOS displays and logs the following DIMM error messages:

NODE-

n Memory Configuration Mismatch

The following conditions will cause this error message:

The DIMMs mode is not paired (running in 64-bit mode instead of 128-bit
mode).

The DIMMs’ speed is not same.

The DIMMs do not support ECC.

The DIMMs are not registered.

The MCT stopped due to errors in the DIMM.

The DIMM module type (buffer) is mismatched.

The DIMM generation (I or II) is mismatched.

The DIMM CL/T is mismatched.

The banks on a two-sided DIMM are mismatched.

The DIMM organization is mismatched (128-bit).

The SPD is missing Trc or Trfc information.

DIMM Fault LEDs

When you press the Press to See Fault button on the motherboard or the mezzanine
board, LEDs next to the DIMMs flash to indicate that the system has detected 24 or
more CEs in a 24-hour period on that DIMM.