Error Handling

63

Handling Mismatching Processors

This section lists facts and considerations about how the server handles mismatching
processors.

The BIOS performs a complete POST.

The BIOS displays a report of any mismatching CPUs, as shown in the following
example:

No SEL or DMI event is recorded.

The system enters Halt mode and the following message is displayed:

AMIBIOS(C)2003 American Megatrends, Inc.

BIOS Date: 08/10/05 14:51:11 Ver: 08.00.10

CPU : AMD Opteron(tm) Processor 254, Speed : 2.4 GHz

Count : 3, CPU Revision, CPU0 : E4, CPU1 : E6

Microcode Revision, CPU0 : 0, CPU1 : 0

DRAM Clocking CPU0 = 400 MHz, CPU1 Core0/1 = 400 MHz

Sun Fire Server, 1 AMD North Bridge, Rev E4

1 AMD North Bridge, Rev E6

1 AMD 8111 I/O Hub, Rev C2

2 AMD 8131 PCI-X Controllers, Rev B2

System Serial Number : 0505AMF028

BMC Firmware Revision : 1.00

Checking NVRAM..

Initializing USB Controllers .. Done.

Press F2 to run Setup (CTRL+E on Remote Keyboard)

Press F12 to boot from the network (CTRL+N on Remote Keyboard)

Press F8 for BBS POPUP (CTRL+P on Remote Keyboard)

******** Warning: Bad Mix of Processors *********

Multiple core processors cannot be installed with single core

processors.

Fatal Error... System Halted.