F : set active unit number – Sony DVS-V3232B/V3232M User Manual

Page 119

Advertising
background image

5-47

ROUTING SWITCHER SYSTEM (E)

5-3. Setting Items of the Primary Station on Monitor S-BUS (BKDS-V3292B only)

SET MONITOR FUNCTION DVS-V6464B Monitor Bus I/F V2.10

MODIFICATION COMMAND

F: SET SCTIVE UNIT NUMBER

M: SELECT MONITOR FUNCTION (COMBINED)

R: CALL SECONDARY STATION

Ctrl-E:RETURN TO MENU

ENABLE ACTIVE UNIT FOR STATION NUMBER DVS-V6464B Monitor Bus I/F V2.10

1 2 3 4 5 6 7 8 9 10 1112131415 1617181920

+

001-020 M E E E E E E E E E E E E E E E E E E E

021-040 E E E E E E E E E E E E E E E E E E E E

041-060 E E E E E E E E E E E E E E E E E E E E

061-080 E E E E E

081-100

101-120

121-140

141-160

161-180

181-200

201-220

221-240

241-254 Å

* * * * * *

CTRL-E:RETURN TO MENU

5-3. Setting Items of the Primary Station

on Monitor S-BUS (BKDS-V3292B
only)

Used for setting the units on the monitor S-BUS.

Menu Screen of the Primary Station on Monitor S-BUS

Setting Procedure of Monitor Function

1.

Select the menu item [R] of the primary station in

order to call the menu screen of the secondary station
set as the primary station on the monitor S-BUS.

2.

Select the menu item [M] to call the menu screen of
the primary station on the monitor S-BUS.

3.

Set the menu item [F] and [M].

4.

Select the menu item [R] to call the secondary station

on the monitor S-BUS.

5.

Set each menu item on the screen.

6.

Press [Ctrl]

_ [Z] to return to the menu screen of the

primary station on the monitor S-BUS.

7.

Set each item of all secondary stations, repeating the
procedure of step 4 to 6.

8.

Press [Ctrl]

_ [D] to return to the menu screen of the

primary station on the standard S-BUS.

n
If there are multiple monitor S-BUS data links, repeat the
procedure of step 1 to 8 for each link.

F : SET ACTIVE UNIT NUMBER

Purpose

This menu is used to enable the units connected to the data

link of the monitor S-BUS to communicate.

Setting Procedure

1.

Select menu item [F].

2.

Select the secondary station using the cursor whose
communication will be valid.

3.

When [Enter] is pressed, the setting displayed will
change “E”

“Blank”

“E”. Only the secondary

stations displayed with “E” are valid. (“M” indicates
the primary station.)

4.

When [Ctrl]

_ [E] is pressed, the menu screen of the

primary station on the monitor S-BUS will be dis-

played.

n
As the response will become slower if there are many

secondary stations, make the secondary stations not
connected invalid.

*” indicates out of the control area.

Example of Setting Screen

m
1.

Station ID of the primary station is always 1 regardless

of the DIP switch setting on the CPU board.

2.

Station ID of the secondary station is deter mined with

the DIP switch setting. Do not assign the same
number on two or more units as station ID on both

standard S-BUS and monitor S-BUS.
Number that can be registered as secondary s station