W: system status log, X : display s-bus communication – Sony DVS-V3232B/V3232M User Manual

Page 95

Advertising
background image

5-23

ROUTING SWITCHER SYSTEM (E)

5-1. Setting Items of the Primary Station

SYSTEM STATUS LOG DVS-V6464B V2.10 STATION NUMBER 1

1990.10.12-15:42 S-BUS LINK DISCONNECTED

1990.10.27-09:28 STARTED BY BKS-R1601 Ver3.10 IN STATION 11

1990.11.03-05:31 STARTED BY BKS-R3204 Ver3.11 IN STATION 32

1991.01.14-13:51 MISSING REFERENCE SIGNAL IN STATION 1

1991.02.01-11:15 POWER SUPPLY UNIT B DOWN IN STATION 4

1991.02.04-06:11 X-POINT ERROR IN STATION 1

-- end --

Ctrl-E:RETURN TO MENU

S-BUS COMMUNICATION TRACE ON

STATION No.011 01 01 0B 03 0E 00 08

STATION No.015 01 09 0F 03 0E 00 08

STATION No.011 01 01 0A FF 01 00 01

STATION No.011 01 01 0F FF 01 00 01

TRACE OFF

Ctrl-E:RETURN TO MENU

W: SYSTEM STATUS LOG

Purpose

This menu is used to check the error during self-diagnosis

of each station, the status of the S-BUS circuit, and the
time of events.

Example of Display

Operation Procedure

1.

Select menu item [W].

2.

When all status cannot be displayed on the screen,

_ _ more _ _ ” will be displayed at the bottom of

the screen. Press [SPACE] key to display the next

status. When all status have been displayed, “

_ _ end

_ _” will be displayed.

3.

Press [Ctrl]

_ [E] to return to the menu screen.

System Status Screen

Refer to “6. Confirmation of Function” for detail of the

system status screen.

n
. To erase the LOG contents in DVS-V3232B/V6464B,

set the S3 switch on the CPU-149 board to “C” (Clear)
and then press the S5 switch (Reset).

After erasing, be sure to return the S3 switch to “0” and
press the S5 switch (Reset) again.

. To erase the LOG contents in HDS-V3232, set the S2

switch on the CPU-251 board to “C” (Clear) and then

press the S8 switch (Reset).
After erasing, be sure to return the S2 switch to “0” and

press the S8 switch (Reset) again.

X : DISPLAY S-BUS COMMUNICATION

Purpose

This menu is used to display the S-BUS data received at

the primary station.

Setting Procedure

1.

Select menu item [X].

2.

To stop the scroll, press [Ctrl]

_ [E]. (“TRACE

OFF” will be displayed at the bottom of the screen.)

3.

The menu screen will be returned when [Ctrl]

_ [E] is

pressed again.

Example of Display

n
For details on the contents of the display, refer to the S-
BUS Protocol Manual.

Advertising