Sony DVS-V3232B/V3232M User Manual

Page 139

Advertising
background image

6-9

ROUTING SWITCHER SYSTEM (E)

DIFFERENT CHECK SUM= ???? IN STATION

* * *

Check sun value

S-BUS LINK DISCONNECTED

CHANGED OVER TO BACKUP CPU IN STATION

* * *

STARTED BY

* * * _ * * * * * Ver * .* * IN STATION * * *

6-6. Function Check with Control Terminal

Content :

This message is displayed when an error has been detected as the result of ROM

checksum and RAM writing tests performed after resetting the unit.

Countermeasure : Replace the corresponding ROM.

n
This error message will be displayed even after the ROM has been replaced. This is normal. Execute the

menu item [J: RECALL MAIN TABLE] from the control terminal, and reset the corresponding unit once
again for the unit to begin operating normally.

Content :

This message is displayed when the S-BUS data link has been disconnected some-
where.

Countermeasure : Check the connections between the S-BUS line and each station, and check that unused

S-BUS ports or the ends of S-BUS lines have been terminated with 75

Z. One method

to search for the disconnected sections is using the menu item [R: CALL SECOND-

ARY STATION] and checking for responses.

n
Be sure to terminate unused S-BUS ports with 75

Z. When a disconnection has been detected, the

primary station automatically performs 75

Z termination and restarts communication with the stations

just before the disconnection. In this case, some stations may not be able to communicate even though

they are connected.

Content :

This message is displayed when an error has occurred in the CPU board during opera-
tions, and it is changed over to the backup CPU board.

Countermeasure : Remove the main CPU board, and repair or replace it with a new one.

Content :

This message is displayed when the switcher is restarted due to instantaneous power
failure, etc., or when the power supply is turned ON.