ROUTING SWITCHER SYSTEM (E)

5-7. Initialization of Table Data

HDS-V3232 :

Initializing Procedure

Corresponding Menu Items

1

1. Set the test switch (S2) on the CPU-251 board to “D”.

All items of the primary and secondary stations.

2. Press the reset switch (S8).

2

1. Set the test switch (S2) on the CPU-251 board to “C”.

[W : SYSTEM STATUS LOG]

2. Press the reset switch (S8).

3

Select the menu item [K : RESET TO DEFAULT TABLE]

All items of the primary station excluding the

of the primary station and press

[Y]

.

following 4 items.

.

[H : SET GLOBAL PHANTOM]

.

[N : SET DESCRIPTION NAME GROUP]

.

[O : SET TIE LINES]

.

[W : SYSTEM STATUS LOG]

4

Select the menu item [K : reset To default table]

All items of the secondary station excluding

of the secondary station and press

[Y]

.

the crosspoint data.

5

Select the menu item [U : SELECT REMOTE PROTOCOL]

[U : SELECT REMOTE PROTOCOL]

of the secondary station and press

[F2]

(DEFAULT).

n
The primary station of HDS-V3232 does not have the menu item[S].

The secondary station of the menu item [Z] of [SWITCHING FIELD] only.

5-7-2. Default Values Initialization

Item

Default Value

Primary station

[B : SET SOURCE/DEST TYPE]

TYPE : 0=IN, 1=OUT, 2-F=None
NAME : IN001-IN512, OUT001-OUT512

[E : SET LEVEL TABLE]

All levels of all destination is ENABLE
Level name : 1, 2, 3....7, 8

[F : SET ACTIVE UNIT NUMBER]

DVS-V3232B : STATION 2-33 ENABLE
DVS-V6464B : STATION 2-65 ENABLE

[H : SET GLOBAL PHANTOM]

Not set

[J : NAME STYLE]

Type

+

Num (“Type

+

Number” name mode)

[L : SET PHYSICAL ASSIGNMENT]

Physical location number=Virtual location number

[M : SET INHIBIT TABLE]

Not set

[N : SET DESCRIPTION NAME GROUP]
[O : SET TIE LINES]
[P : CHANGE PASSWORD]

[S : SELECT INDICATION COLOR]

OFF

[U : SELECT CONTROL MODE]

All channels : DIRECT

[V : SELECT WARNING DISPLAY]

OFF

[W : SYSTEM STATUS LOG]

NO LOG

[Z : SET UNIT DETECTABLE]

All STATION : OFF

Secondary station

[A : SET UNIT LOCATION ]

No OFFSET

[U : SELECT REMOTE PROTOCOL]

The input /output number is 1:1.

[Z : SELECT SDI FORMAT]

4:2:2, SWITCHING FIELD=FIELD

Crosspoint data

The input/output number is 1:1.