ROUTING SWITCHER SYSTEM (E)

1-2. System Control

*

1 : There are two kinds of cart protocol due to the control area.

Unless otherwise noted, “cart protocol” in this manual mean the cart plus protocol.

1-2-3. 9-pin remote control

The Sony digital routing switcher can be controlled from external control units connected to the RE-
MOTE 2 (D-sub 9-pin) using RS-422A. For DVS-V3232B/V6464B, BKPF-R70 and HDS-V3232, the

functions performed by 9-pin remote control, can especially be upgraded to a great extent. The following
three kinds of 9-pin remote protocols can be used.

. Sony production switcher protocol
. Sony audio mixer protocol
. Sony cart protocol

n
The protocol that can be used depends on the models (refer to Section 1-2-1).
BKPF-R70 is controlled by Sony cart protocol only.

The DVS-V3232B/V6464B, BKPF-R70 and HDS-V3232 can be switched between the “direct mode” in

which they are controlled directly and to the “S-BUS conversion mode” in which cart protocol commands
are converted to the S-BUS protocols.

In the direct mode, the switchers can be controlled individually. In the S-BUS conversion mode, up to
254 switchers on the S-BUS line (including the primary station) can be controlled.

For DVS-V3232B/V6464B/V1616/A3232 and HDS-V3232, the S-BUS and 9-pin remote control lines
are connected to REMOTE 1 and 2 respectively and can be switched freely. Other switchers can be

connected to either control line.

m
1.

In the direct mode, the protect and secret functions set on the S-BUS protocol are not avail able.

2.

In the S-BUS conversion mode, the “UA2” data specified by the cart protocol will be converted to
the level values on S-BUS protocol.

In this mode, the protect and secret functions set on S-BUS protocol are available. (However, these
functions cannot be set on the 9-pin remote control and the contents of the setting cannot be checked,

either.)

3.

The number of input/output signals that can be controlled on each protocol is as follows.

Protocol

Control Area

Cart Protocol

*

1

Cart

1-16

Cart plus

1-256

Audio mixer protocol

1-128

Production Switcher Protocol

1-127

4.

When several DVS-V6464Bs are connected in a cascade and the input bus number is in creased, if

controlled by the 9-pin remote, there is the case no signal is output.
To avoid such case, use the S-BUS conversion mode.