ROUTING SWITCHER SYSTEM (E)

5-1. Setting Items of the Primary Station

SELECT CONTROL MODE

DVS-V6464B V2.10 STATION NUMBER 1

CHANNEL A --- REMOTE FUNCTION = CONVERT RS422(CART+) to S-BUS

CHANNEL B --- REMOTE FUNCTION = DIRECT

Ctrl-E:RETURN TO MENU

U : SELECT REMOTE

Purpose

This menu is used to control the routing switcher using the
9-pin remote (REMOTE 2), and to set the control mode to

the DIRECT mode or the S-BUS conversion mode.

Setting Procedure

1.

Select menu item [U].

2.

Select channel using the cursor keys.

3.

Press [Enter], and the setting condition displayed will

be changed.
DIRECT

CONVERT RS422 (CART

+) to S-BUS

Example of Setting Screen

DIRECT:

In this mode commands received using RS-422A are not
converted to those for the S-BUS (REMOTE 1) and are
directly used for controlling the receiving station. If this

mode is selected, a protocol must be selected at the
secondary station.

CONVERT RS-422 (CART

+) to S-BUS

This mode converts commands received using the RS-
422A to those for the S-BUS.

n
How to use UA2 Code:
The original use of the UA2 code in the RS-422A protocol

is to identify the multiple equipments which are connected
by loop-through connection, and be controlled.

Each equipment is controlled by the control command with
UA2 code which corresponds to the unit address of each

equipment.

The UA2 code is converted to the level control command
when the RS-422A commands are converted to the S-BUS

levels.

The following examples show how UA2 codes are con-
verted to the S-BUS level.

UA2 = 01

00000001

S-BUS level 1

UA2 = 02

00000010

S-BUS level 2

UA2 = 04

00000100

S-BUS level 3

UA2 = 08

00001000

S-BUS level 4

UA2 = 10

00010000

S-BUS level 5

UA2 = 20

00100000

S-BUS level 6

UA2 = 40

01000000

S-BUS level 7

UA2 = 80

10000000

S-BUS level 8

UA2 = FF

11111111

S-BUS All level

The following combinations of levels are also possible.

UA2 = 03

00000011

S-BUS level 1 and 2

UA2 = 07

00000111

S-BUS level 1, 2 and 3

n
The S-BUS conversion mode can be used only when the
primary station is controlled by the 9-pin remote control.

Therefore, use the DIRECT mode whenever a secondary
station is controlled by the 9-pin remote control.