25 (e) – Sony HDS-X5800 User Manual

Page 33

Advertising
background image

1-25 (E)

HDS-X5800

<Switches>
n
The two CPU-339 boards that are inserted in slots A and B, must have the exactly same setup.

S701 (D-8) : Station ID/Unit IP setting switch
8-pin piano-type switch

Set the unit ID for communication with external devices.
Even if the setting is changed while the power is on, the unit ID is not updated.
In order to change the unit ID, change the setting. Then either turn off the main power and back on, or
press the reset switch on the CPU-339 board.

Set the station ID of the HDS-X5800 when the HDS-X5800 is connected to the S-BUS data link as
follows.
When the HDS-X5800 is used as the primary station, the station ID is set to “1” regardless of setting of
this switch.
When the HDS-X5800 is used as the secondary station, set the station ID to any number other than “0”,
“1” and “255”. Be careful not to duplicate the same number of the other equipment in the secondary
station when setting the station ID.

Setup example

When the switch S703-6 is set to CLOSE (DOWN position), this switch is used for the IP address when
connected to the DATA LAN and is fixed to “10.64.5.1”.

OPEN

1

2

3

4

5

6

7

8

Factory setting
( indicates the switch lever position.)

[1]

[2]

[4]

[8] [16] [32] [64] [128]

1

1

2

3

4

5

6

7

8

0

OPEN

When the setup value is 8

<Setup value>

8 :

30 :

254 :

0 0 0 1 0 0 0 0
0 1 1 1 1 0 0 0

0 1 1 1 1 1 1 1

1 ; OPEN (Up position)
0 ; CLOSE (DOWN position)

(16

+ 8 + 4 + 2)

(128

+ 64 + 32 + 16 + 8 + 4 + 2)

1-11. Setting the On-Board Switches and Description of LEDs