1-27 (E)

HDS-X5800

OPEN

1

2

3

4

5

6

7

8

Factory setting
( indicates the switch lever position.)

BIT2 : Cross-level Tie Line function valid/invalid

selector switch

Set this switch when you want to enable the cross-level tie
line function when the tie line system is constructed using
the HDS-X5800. Even if the setting is changed while the
power is on, the operation mode is not updated.
In order to change the operation mode, change the setting.
Then either turn off the power and back on, or press the
reset switch on the CPU-339 board.

UP (OPEN) position : Cross-level tie line function is

made valid.

DOWN position :

Cross-level tie line function is
made invalid.

BIT3 : Tie Line full display function valid/invalid

selector switch

Set this switch when you want to enable the cross-level tie line
full display function when the tie line system is constructed
using the HDS-X5800.

UP (OPEN) position : Cross-level tie line full display

function is made valid.

DOWN position :

Cross-level tie line full display
function is made invalid.

BIT4 : SYNC/ASYNC selector switch
Used to select whether the communication on the RE-
MOTE1 data link is carried out in synchronization with the
input reference signal that is connected to the REF IN A
connector, or is communicated asynchronous with the
input reference signal. However, the routing switcher
system will operate in the asynchronous mode if the
reference video signal is not input to the REF IN A
connector even if this switch is set to the SYNC position.
Even when a setting is changed while the power is on, the
setting is reflected on the operation of the HDS-X5800.

UP (OPEN) position : ASYNC (asynchronous mode)
DOWN position :

SYNC (synchronous mode)

BIT5 : Table data size selector switch
Used to select whether the S-BUS table data size that is
output is 128 bytes or 32 bytes while the HDS-X5800 is a
primary station in the S-BUS data link connected by the
REMOTE1 B connector. When this switch is set to the 32
bytes mode, set the S703-4 to the DOWN position. When
the sync selector of the REF IN A channel is set to ODD
using the setup menu while the sync signal is being input
to the REF IN A connector, the S-BUS control enters the
frame sync mode. In the frame sync mode, the connectable
station ID is fixed to position 2 to 15. Even when a setting
is changed while the power is on, the setting is reflected on
the operation of the HDS-X5800.

UP (OPEN) position : 32 bytes
DOWN position :

128 bytes

1-11. Setting the On-Board Switches and Description of LEDs

BIT5 to BIT7 : Baud rate selector switch

BIT5 : REMOTE1 A
BIT6 : REMOTE1 C
BIT7 : REMOTE1 D

Sets the baud rate when the HDS-X5800 is connected to
the S-BUS data link using the above connectors.
Set BIT5 to BIT7 in accordance with the connectors used.
All of the equipment that are connected to the same S-BUS
data link must have the same setting for the baud rate
speed. Even when a setting is changed while the power is
on, the setting is reflected on the operation of the HDS-
X5800.
If there is any possibility to disconnect the cables between
the equipment while they are operating, set the switch to
the DOWN position.

UP (OPEN) position : 1250 kbps
DOWN position :

312 kbps

n
Baud rate of the REMOTE1 B is fixed to 312 kbps.

BIT8 : Cascade selector switch
Used to extend the inputs depending on the cascade
connection. Set this switch to the UP (OPEN) position in
the HDS-X5800s that connect to the cascade.
Even if the setting is changed while the power is on, the
operation mode is not updated.
In order to change the operation mode, change the setting.
Then either turn off the power and back on, or press the
reset switch on the CPU-339 board.

S703 (E-8) :
8-pin piano-type switch

BIT1 : Virtual matrix function valid/invalid

selector switch

Set this switch when you want to use the virtual matrix
function. Even if the setting is changed while the power is
on, the operation mode is not updated.
In order to change the operation mode, change the setting.
Then either turn off the power and back on, or press the
reset switch on the CPU-339 board.

UP (OPEN) position : Virtual matrix functions.
DOWN position :

Virtual matrix does not function.