External Control Commands

External Control Commands

Overview

The XCI-SX1/V3 can be controlled externally from a
host device via a serial communication and telnet using
such communication softwares as “HyperTerminal” or
“Tera Term.”

Serial Communication
Specifications

The serial communication system for the XCI-SX1/V3
is an asynchronous method compliant with RS-232C.
The following table shows the transmission control
specifications.

Baud rate

115200/57600/38400/19200/9600/4800 [bps]
Default setting: 38400 [bps]

Data bits

8

Parity

None

Stop bit

1

Flow control

None

Authentication

None

The external interface for serial communication is RS-
232C DCE (Data Communication Equipment) whose
connector form is D-sub 9pin(male).
When connecting the XCI-SX1/V3 to a PC, use a cross
cable.

TXD

1

RXD

2

GND

3

NC

4

NC

5

NC

6

1

2

RXD

3

TXD

4

5

GND

6

7

8

9

XCI-SX1/V3 RS-232C connection

6PIN

D-SUB 9PIN

Telnet Communication
Specifications

The following table shows the specification for telnet
communication.

Port Number

23

Authentication

login, password authentication

For the login, use the following login account.

user:

admin

password: 1227

Telnet Authentication
Specification

When you access the XCI-SX1/V3 from external
equipment, the following message appears on the
monitor.

SMARTCAM Telnet Server
SMARTCAM login:

Enter the login account and then the password.

SMARTCAM Telnet Server
SMARTCAM login: admin
password:

******