Power connection – Southbend SB1023 User Manual

Page 17

Advertising
background image

For Machines Mfg. Since 8/09

Model SB1023

-15-

P R E P A R A T I O N

Power Connection

Electrocution or fire
may occur if machine is
ungrounded, incorrectly
connected to power, or
connected to an undersized
circuit. Use a qualified
electrician to ensure a safe
power connection.

Once your machine is set up and assembled as
previously described in this manual, it is ready to
be connected to the power source.

Note About Extension Cords: Using an
incorrectly sized extension cord may decrease the
life of electrical components on your machine.

SB1023 110V (Prewired)

Required Power Source ........ 110V, 1-Phase, 60Hz
Full Load Amp Draw .............................. 9.5 Amps
Phase ..........................................................1-Phase
Frequency ...................................................... 60 Hz
Minimum Circuit Size ............................. 15 Amps
Included Plug ...................................... NEMA 5-15
Minimum Extension Cord Size ................ 14 AWG
Maximum Extension Cord Length ................ 50 ft.

SB1023 (220V Option)

Required Power Source ........ 220V, 1-Phase, 60Hz
Full Load Amp Draw ................................. 5 Amps
Phase ..........................................................1-Phase
Frequency ...................................................... 60 Hz
Minimum Circuit Size ............................. 15 Amps
Recommended Plug/Receptacle .......... NEMA 6-15
Minimum Extension Cord Size ................ 16 AWG
Maximum Extension Cord Length ................ 50 ft.

220V Conversion for SB1023

Wiring diagrams are provided in the back of
this manual (Page 36) showing the Model
SB1023 wired for both 110V and 220V.
Refer to these diagrams when following this
procedure. Additionally, you must purchase the
220V conversion kit in order to complete the
conversion. Call our parts department at
(417) 886-2954 and order part number
PSB1023180.

To convert the Model SB1023 to operate on
220V power:

1. DISCONNECT MACHINE FROM POWER!

2. Rewire the motor for 220V, as shown in the

diagram on the inside of the motor junction
box. If there is not a diagram in the junction
box, use the diagram in this manual (Page
36
).

3. Replace the contactor on the machine with

the contactor from the 220V conversion kit.
Set the amp dial to 5.5A

4. Replace the power cord plug with a NEMA

6-15 plug.

Advertising