110 vac, Motor, 15 plug (as recommended) – Southbend SB1023 User Manual
Page 39: Control panel (viewed from behind) electrical box, Electrical box control panel
Advertising
For Machines Mfg. Since 8/09
Model SB1023
-37-
E L E C T R I C A L
SB1023 Wiring Diagram 110V
Figure 44. Spindle motor & pump motor locations.
Figure 45. Electrical box & control panel location.
Spindle
Motor
AM
P
10
16
TH
E
R
MAL
REL
A
Y
Allen Bradley
193T
A
C
CON
T
A
CT
OR
Allen Bradley
C0
9
4
00
13
5
7
L1
L2
L3
L4
24
6
8
T1
T2
T3
T4
95
9
6
10.5A
NO
NC
9
7
98
U
U
V
V
2
2
S
S
GND
GND
S
S
R
R
R
R
R
4
4
4
4
4
3
3
3
3
3
Run Capacitor
200MFD
125VAC
GND
V
U
3
1
4
2
Neutral
Hot
Ground
110 VAC
5-15 Plug
(As Recommended)
ON BUTTON
(Viewed From
Behind)
OFF BUTTON
(Viewed From
Behind)
Motor
Control Panel
(Viewed From
Behind)
Electrical Box
2
1
3
4
Electrical Box
Control Panel
Advertising