OUTPUT TERMINALS

TAPE END OUT Terminal

During recording, when the end of the tape is reached
or when the tape counter reading indicates 7 hours 57
minutes or more, the output becomes 0V (Low).

To reset the output, press the STOP or EJECT button.

During autorepeat recording, when the end of the tape
is reached, the output becomes 0V (Low) for about 2
seconds only.

TAPE END OUT Terminal Output Setting

1

Press the MENU button until the (SET UP 3) menu is
displayed.

@@@@@@@<SET@UP@3>

*ALARM@MODE@@@@@@@Y1

*ALARM@SPEED@@@@@@8H

*ALARM@DURATION@@@20S

*VERTICAL@SYNC@@@@Y

*EXT@TIME@ADJ.@@@@01:00

*TAPE@IN@MODE@@@@@STOP

*TAPE@END@MODE@@@@REW

*TAPE@END@OUT@@@@@-3M

*CLOG@DETECT.@@@@@Y

*SERIES@REC@IN@@@@N

2

Press the

]

button until the “TAPE END OUT” setting

is flashing.

3

Press the

l

(or

j

) button, to select the desired

output mode.

– 3M . . . . . . . . The output becomes 0 V (Low)

when the tape counter reaches
“7:57:00” and/or when the tape
reaches the end.

END . . . . . . . . The output becomes 0 V (Low)

when the tape reaches the end.

4

Press the PAUSE/SEARCH button to save the setting.

SW OUT Terminal

When recording, a pulse signal is output at the SW OUT
terminal.

This terminal is usually connected to the switch input (SW
IN) of devices like a camera switcher unit, or a quad
compressor.

SW OUT Terminal Output Setting

1

Press the MENU button until the (SET UP 4) menu is
displayed.

@@@@@@@<SET@UP@4>

*SW@OUT

@@TIMING@@@@@@@@@@FIELD

@@FIELD@@@@@@@@@@@01

@@8H@@@@@@@@@@@@@@Y

*THREAD@CHECK@@@@@Y

*VIDEO@LOSS@@@@@@@N

*REC@SPEED@@@@@@@@N

*EJECT@SET

@@EJECT@MODE@@@@@@EJECT1

@@OPERATION@@@@@@@SLAVE

2

Press the

l

(or

j

) button to set “FIELD” or “FRAME”,

then press the

]

button.

FIELD . . . . . . . 1 pulse is output after each set

number of fields.

FRAME. . . . . . 1 pulse is output after each set

number of frames.

3

Press the

l

(or

j

) button to set the desired pulse

signal interval, then press the

]

button.

If “TIMING” is set to FRAME (see step

2

),

“FRAME” will be indicated instead of “FIELD”.

Available settings are:

FIELD . . . . . . . 01, 02, 03, 04, 05, 10, 30 or 60 field

FRAME. . . . . . 01, 02, 03, 04, 05, 10, 30 or 60

frame

4

Press the

l

(or

j

) button to set the desired “8H (or

6H)” mode.

If the “TAPE” in the (SET UP 5) menu is set to
“T-120”, “6H” will be indicated instead of “8H”.

Y . . . . . . . . . . . When recording in 8-hour (or

6-hour) mode, a pulse signal is
output.

N. . . . . . . . . . . When recording in 8-hour (or

6-hour) mode, a pulse signal is
not output.

5

Press the PAUSE/SEARCH button to save the
settings.

Tape end or 7:57:00

5V (H)

0V (L)

(Output impedance: 5.7 k

)

Output reset

5V (H)

0V (L)

(Output impedance: 5.7 k

)

FIELD: 16.7 msec.
FRAME: 5 msec.