138

APPENDIX

Drive circuit

The recommended drive unit is shown below.

Notes

• Peripheral Units 1 and 2 cannot be driven simultaneously.

• For continuous driving, do not use drive duty greater than 20%.

• The status of the compulsion switch can be known from the following.

Star mode

: The status of the compulsion switch can be known by

using the automatic status function or <ENQ>
commands. In the case of ENQ status, bit 7 will be
“1”when pin No. 6 of the peripheral unit drive circuit
is high (switch on).

ESC/POS mode : The status of the compulsion switch can be known by

using the automatic status function, <DLE><EOT>n,
and <ESC>“u”n commands.

Parallel interface: The status of the compulsion switch can be known by

pin No. 34 on the parallel interface connector. When
the compulsion switch is on, pin No. 34 will be low.
This can be checked by using the compatibility mode.

• Minimum resistance for coils L1 and L2 is 24

.

7824

F.G

TR1

M-GND

TR2

M-GND

TR3

+5V

+24V

R1

R2

6

5

4

3

2

1

L1

L2

R3
4.7k

1/4W

Frame
ground

Printer side

User side

D1

D2

Peripheral
unit 1

With shield

Peripheral
unit 2

Compulsion
switch

Drive output: 24V, 1.0A max.