4 - 10 Symbol DS6708 Digital Scanner Product Reference Guide

Decode Session Timeout

Parameter # 88h

This parameter sets the maximum time decode processing continues during a scan attempt. It is programmable in
0.1 second increments from 0.5 to 9.9 seconds. The default timeout is 9.9 seconds.

To set a Decode Session Timeout, scan the bar code below. Next, scan two numeric bar codes from

Appendix D,

Numeric Bar Codes

that correspond to the desired on time. Enter a leading zero for single digit numbers. For

example, to set a Decode Session Timeout of 0.5 seconds, scan the bar code below, then scan the 0 and 5 bar
codes. To correct an error or change the selection, scan Cancel on

page D-2

.

Timeout Between Decodes, Same Symbol

Parameter # 89h

Use this option in presentation (scanstand) mode to prevent the beeper from continuously beeping when a symbol
is left in the digital scanner’s field of view. It is programmable in 0.1 second increments from 0.0 to 9.9 seconds.
The default interval is 0.6 seconds.

To select the timeout between decodes for the same symbol, scan the bar code below, then scan two numeric bar
codes from

Appendix D, Numeric Bar Codes

that correspond to the desired interval, in 0.1 second increments.

Decode Session Timeout

Timeout Between Decodes, Same Symbol