4. Settings Required for Network Printing

18

4.2

To Make the Settings on the Controller Side

Network settings on the controller side may be made either from the copier control
panel or through Network Management Utility Light used on a PC connected to the
network. Use of Network Management Utility Light allows detailed settings that
cannot be made from the copier control panel to be made. For the details of
Network Management Utility Light, see “Appendix B. How to Use Network
Management Utility Light.” ☞p.138

To use Network Management Utility Light, it is necessary to first set the IP address
by following the procedure given below.

IP Address Setting

1. On the control panel of the copier, select “Utility” – “Admin. Mode” and then

enter the password.

2. Select “Network set” – “Common Setting” – “TCP/IP” to open the “TCP/IP”

screen.

3. Make the following settings:

IP Address

: Set the IP address of the controller.

Subnet Mask

: Set the subnet mask for the network to be

connected.

Gateway Address

: Set the default gateway address for the network to

be connected.

Check with the network administrator on these three items in advance.

4. Turn OFF the Power Switch OFF of the copier.

Turn the Power Switch ON again, then the settings are effective.

4334P152CA