Feeding documents that require special handling, Calibrating the scanner – Kodak 6J7611A User Manual

Page 27

Advertising
background image

A-61500 May 2010

3-11

Feeding documents
that require special
handling

The gap release lever allows you to manually adjust the space between
the feed module and separation roller for documents that require
special handling; i.e. documents that are badly torn. If you are in doubt
about whether a damaged document can be transported through the
scanner, use the gap release lever and manually feed the document.
Using the scanner in continuous feed mode is recommended when
handling special documents.

1. Press and hold the gap release lever — this provides clearance to

ease document feeding.

2. Push the document into the elevator tray. If more than one

document is to be scanned, feed them one at a time.

3. After the document(s) has been fed, release the gap release lever.

Calibrating the
scanner

There are two types of calibration that can be performed on the i600/
i700 Series Scanners: Image calibration and Ultrasonics calibration.

Image calibration: optimizes the optical system in your scanner in

order to achieve the best overall quality of scanned images. Frequent
calibration is not needed or recommended.

IMPORTANT: If the White Background Accessory is installed, it must be

replaced with the black background strip, and the
scanner must be rebooted prior to calibration.

Ultrasonics calibration: ensures that the ultrasonics system that

detects multi-feeds and document edges is properly adjusted for best
performance. Frequent calibration is not needed or recommended.

Advertising