Image calibration – Kodak 6J7611A User Manual

Page 28

Advertising
background image

3-12

A-61500 May 2010

Image calibration

Use the calibration target provided with your scanner. Be sure to use a
good, clean calibration target. Additional calibration targets can be
ordered. See Chapter 5, “Supplies and accessories” for ordering
information.

NOTE: The screens shown in this section are for the TWAIN

Datasource. The screens displayed on your system may be
different.

1. Open the pod and clean the imaging guides. Refer to the

maintenance procedures in Chapter 5.

2. If the lamps have not been on, allow the lamps to warm up for

90

seconds.

3. Center the side guides in the elevator tray and output tray.

4. Place the calibration target in the elevator tray.

5. Open the Scan Validation Tool.

6. Select Kodak Scanner: i600 or Kodak Scanner: i700.

The main Kodak Scanner window will be displayed.

Advertising