Kohler Command CV730 User Manual

Page 137

Advertising
background image

8.21

8

Section 8

Electrical System and Components

Figure 8-33. Connections for Testing Charging System.

Figure 8-32.

3. Plug the tester into the proper AC outlet/power

supply for tester being used. Turn on the power
switch. The ‘‘POWER’’ light should be
illuminated and one of the four status lights may
be on as well. See Figure 8-26. This does not
represent the condition of the part.

4. Press the ‘‘TEST’’ button until a “click” is heard

and then release. See Figure 8-27. Momentarily
either the ‘‘HIGH’’, ‘‘LOW’’, or ‘‘SHORT’’ light
will flash.

a. If the “HIGH” light flashes on/off, the part is

good and may be used.

b. If any other light is displayed* the rectifier is

faulty and should not be used.

*NOTE: A flashing “LOW” light can also occur as a

result of an inadequate ground lead
connection. Make certain connection location
is clean and clamp is secure.

DC Voltmeter

Rectifier-Regulator

Flywheel
Stator

Ammeter

Battery

(-)

(+)