Kohler Command CV730 User Manual

Page 65

Advertising
background image

5.31

Section 5

Fuel System and Governor

5

Sensitivity Adjustment

Governor sensitivity is adjusted by repositioning the
governor spring in the holes of the governor lever. If
speed surging occurs with a change in engine load, the
governor is set too sensitive. If a big drop in speed
occurs when normal load is applied, the governor
should be set for greater sensitivity. See Figure 5-66
and adjust as follows:

1. To increase the sensitivity, move the spring closer

to the governor lever pivot point.

2. To decrease the sensitivity, move the spring away

from the governor lever pivot point.

High Speed (RPM) Adjustment (Refer to Figures
5-67, 5-68, or 5-69.)

1. With the engine running, move the throttle

control to fast. Use a tachometer to check the
RPM speed.

2. Loosen the lock nut on the high speed adjusting

screw. Turn the screw counterclockwise to
decrease, or clockwise to increase RPM speed.
Check RPM with a tachometer.

3. When the desired RPM speed is obtained,

retighten the lock nut.

NOTE: When the throttle and choke control cables

are routed side-by-side, especially under a
single clamp, there must be a small gap
between the cables to prevent internal
binding. After the high-speed setting has
been completed, check that there is a gap of
at least 0.5 mm (0.020 in.) between the control
cables.

Figure 5-67. Governor Control Connections.

Choke
Control
Cable

Throttle
Control Cable

Z Bend

Choke Linkage

Throttle Control
Lever #2

Choke Control
Lever #1

Kill Switch

Choke
Control
Cable

Throttle
Control
Cable

Kill Switch
Adjusting Screw

Dual Control High
Speed Lever Stop
Screw "Do Not
Remove"

High Speed
Control Lever

High Speed
Adjusting
Screw

Left Side Pull

Right Side Pull

Advertising