Section 4 air cleaner and air intake system – Kohler Command CV730 User Manual

Page 29

Advertising
background image

4.1

Section 4

Air Cleaner and Air Intake System

4

Section 4

Air Cleaner and Air Intake System

Air Cleaners

General

These engines are equipped with a replaceable, high-
density paper air cleaner element. Most are also
equipped with an oiled-foam precleaner which
surrounds the paper element.

Three different types are used. The “standard” type air
cleaner is shown in Figure 4-1. The “commercial
mower” type is shown in Figure 4-2, and the “heavy-
duty” air cleaner is shown in Figure 4-9.

Figure 4-1. Standard Air Cleaner.

Service

Check the air cleaner daily or before starting the
engine
. Check for and correct any buildup of dirt and
debris, along with loose or damaged components.

NOTE: Operating the engine with loose or damaged

air cleaner components could allow
unfiltered air into the engine causing
premature wear and failure.

Precleaner Service (Standard and Commercial
Mower Types)

If so equipped, wash and reoil the precleaner every 25
hours
of operation (more often under extremely dusty
or dirty conditions).

To service the precleaner, see Figures 4-3 or 4-4 and
perform the following steps:

1. Loosen the cover retaining knob or unhook the

latches and remove the cover.

2. Remove the foam precleaner from the paper air

cleaner element.

3. Wash the precleaner in warm water with

detergent. Rinse the precleaner thoroughly until
all traces of detergent are eliminated. Squeeze out
excess water (do not wring). Allow the precleaner
to air dry.

4. Saturate the precleaner with new engine oil.

Squeeze out all excess oil.

5. Reinstall the precleaner over the paper air cleaner

element.

6. Reinstall the air cleaner cover. Secure the cover

with the two latches or the retaining knob.

Figure 4-2. Commercial Mower Air Cleaner.

Advertising