- 11 -

Toilet does not shut off

and water is flowing into

the flush valve overflow.

SYMPTOMS

PROBABLE CAUSE

CORRECTIVE ACTION

Poor flush.

A. Low tank water level.

A. Check water level in tank, adĆ

just per startĆup instructions.

B. Supply stop not fully open.

B. Fully open supply stop.

C. Low bowl water level.

C. Adjust per startĆup instrucĆ

tions.

D. Water pressure below 30 psi.

D. Increase running water presĆ

sure.

Poor rim wash.

A. Same as A, B, C, D for poor flush.

A. Same as A, B, C, D for poor

flush.

A. Defective flush ball.

A. Replace flush ball.

Toilet does not shut off

but water is not flowing

into the overflow.

A. High water level in

tank.

A. Adjust water level. (See startĆ

up instructions.)

B. Leaky float ball.

B. Replace float ball.

C. Leaky float valve seat.

C. Replace seat washer.

Bowl seal does not reĆ

cover.

A. Seal screw needs adjusting.

NOTE: May be caused by temĆ

porary reduced water presĆ
sure.

A. Adjust seal screw per startĆup inĆ

structions.

Toilet leaves an odor.

A. Toilet is dirty.

A. Clean rim holes, bowl, and trapĆ

way with disinfecting bowl
cleaner.

B. Replace toilet.

Toilet overflows.

A. Toilet is clogged.

A. Use plunger to unclog toilet.

C. Plunger needs lubricaĆ

tion.

C. Lubricate plunger with silicone

lube.

D. Plunger needs replacĆ

ing.

D. Replace

plunger.

TROUBLESHOOTING GUIDE FOR RIALTO, SAN RAPHAEL, PILLOW TALK AND CABERNET

B. Crack in bowl allows sewer gas

into the room.

B. Defective or dirty flush valve gasĆ

ket.

B. Clean or replace flush valve

gasket .

Excessive noise.

A. High pressure/high flow

rate.

A. Partially close supply stop.

B. Seal screw not correctly adĆ

justed.

B. Check water seal, readjust per

startĆup instructions.

Advertising