Kohler SIPHON VORTEX LOW PROFILE ONE-PIECE TOILETS K-3402-EB User Manual

Page 3

Advertising
background image

- 3 -

ROUGHINGĆIN AND INSTALLATION

CONSIDERATIONS

Kohler low profile, oneĆpiece toilets are perfect for remodelĆ
ing and new installations. Refer to the roughingĆin drawĆ

ings Figs. #4 - #9.
Always refer to your local codes and the installation inĆ

structions packed with the toilet.

KOHLER LOW PROFILE ONEĆPIECE TOILET
FEATURES

S OneĆpiece design offers contemporary styling.

S Elongated bowl offers a large water area for efficient

waste removal.

S NonĆoverflow design prevents the bowl from overflowing

if the toilet becomes clogged.

S Rialto, San Raphael, Cabernet, and Pillow Talk toilets

flush with 3.5 gallons of water for greater economy.

S TwistĆLock flush valves on new Rialto, San Raphael,

Cabernet, and Pillow Talk toilets offer ease of replaceĆ
ment with no tools.

S Siphon vortex action provides excellent flush and quiet

operation.

S Large water area in bowl aids in effective waste removal.

STARTĆUP AND OPERATION FOR RIALTO,
SAN RAPHAEL, CABERNET, AND PILLOW

TALK TOILETS

For most satisfactory operation of this toilet, 25 to 90 psi

working pressure is required at the fixture. A full 1/2" supĆ
ply stop (K-7653) is recommended. A plastic nut is proĆ

vided with the toilet and must be used to make the supply
connection to the toilet.

1. Water Level Adjustment: Refer to Fig. #10. Turn on

the water supply to the toilet and adjust the water level

in the tank to the Water Line mark on flush valve. To

raise the water level, turn the tank water level on float

valve counterclockwise. To lower the water level, turn

the screw clockwise.

2. Bowl Water Level Adjustment: Use the trip chain to lift

the flush ball in the tank slightly, to allow water to trickle

into the bowl until the water level in the bowl stops risĆ

ing. This is the "seal height" and should be noted for

subsequent adjustment. Flush the toilet and observe

the water level in the bowl after refill. If the water level is

Fig. #10

Adjusting the Float Valve

Seal Screw

Timing Screw

Tank Water Level

Screw

Slotted screw on

newer models

below seal height, turn the seal screw clockwise,

reflush the toilet and recheck the water level. Continue

adjustment until water stops entering the bowl just as

the seal height is reached.

If water continues to flow (in bowl) after water level

reaches seal height, turn seal screw counterclockwise

and reflush toilet. Continue adjustment until water

stops entering the bowl just as the seal height is

reached.

3. High Water Pressure Timing: Note: If toilet is installed

in an area with high water pressure (above 50 psi workĆ

ing pressure), the float valve should be timed. To time

the float valve hold the float rod and flush the toilet. After

the toilet has completed the flush, time the refill from reĆ

lease of rod to valve shut-off.

For K-3397-EB San Raphael, K-3378-EB Pillow

Talk, and K-3408-EB Cabernet. If the time is longer than
34 seconds, no adjustment is required. If time is under 34

seconds, turn timing screw clockwise and recheck timing.
Adjust timing screw until time is between 34 and 36 secĆ

onds. After timing the valve, recheck the bowl water level as
in step #2, to ensure that seal is maintained.

For K-3402-PB Rialto. If the time is longer than 26 secĆ

onds, no adjustment is required. If time is under 26 secĆ
onds, turn timing screw clockwise and recheck timing. AdĆ

just timing screw until time is between 26 and 28 seconds.
After timing the valve, recheck the bowl water level as in

step #2, to ensure that seal is maintained.

Advertising