The explanation of this installation process is based on the assumption that the entire CAP unit
has been properly put together, installed and set up, as described in this installation manual.
The safety instructions in the detailed operating manual for the UFS 740sw must also be followed!

INSTALLATION PROCESS

POLARISATION SETTING

To dismantle/install the planar antenna from the turntable, proceed as follows: (the key names refer to the
remote control for the UFS 740sw receiver)

1. Turn on the receiver at the main switch on the front of the unit.
2. Pressing any of the numeric buttons will bring the receiver into operating mode.
3. If

necessary,

fi rst perform a fi rst installation

4. Wait until the message “Position of Astra is not known. Start a search?” is displayed – cancel this

procedure by pressing the



button.

5. Next, press the



button to go to the main menu and use the



buttons to move to the menu item

“Settings”. Confi rm the selection by pressing the



button.

6. Use

the



buttons to move to the menu item “Antenna Confi guration”. Confi rm the selection by

pressing the



button.

7. Use

the



buttons to select the Elevation menu item and use the numeric pad on the remote control

to enter “400”.

8. Press

the



button and the turntable will move to the selected elevation angle.

9. Turn off the UFS 740 using the main switch on the front and disconnect it from the power.
10. Unscrew the antenna fastening screws on the turntable with a suitable hexagon key (size 5), see

photograph on the right.

11. Carefully lift the antenna off the turntable and exchange the slot for the rubber bushing with cable and

the relevant dummy bushing (depending on the direction you want to move the antenna).

ON THE TURNTABLE

12. You can now refi t the antenna with the desired change of angle (+15° or -15°) (see picture on the

right).

13. Tighten the hexagon socket screws to a torque of 6-7 Nm.
14. Leave the installation location and reconnect the UFS 740sw to the power supply.