This insert operates on a millivolt control system. As such, no

addition power supply is needed for the insert to operate. The

pilot assembly contains a Thermopile, that when heated by the

pilot flame, generates electricity (millivolts, mV=1/1000 of a volt)

that travels to terminal #1. From this terminal it travels through

a black wire to the Vent Safety Snap Switch. If this switch over-

heats through a flue blockage or vent pipe disconnection it will

open, stop the flow of mV and shut the insert off. This switch will

automatically reset (close), when it is cooled down to normal

operating temperature. During normal operation, it is closed

allowing the mV to flow back to the valve, which opens so gas

can flow through.

To check for proper operation, use a multimeter and perform the

system checks shown in Table 4 (and refer to Figure 19).

Thermostat Wire

Wire Size

Maximum Length

1 Gage

100 Feet

14 Gage

64 Feet

16 Gage

40 Feet

18 Gage

5 Feet

0 Gage

16 Feet

Table 

Do not splice any millivolt wires. Refer to Table 3 to determine

the proper gage of wire for the thermostat or wall switch

connections. This table refers to the total length of the wire

(out to the switch and back). The thermostat must be a

millivolt type. A 24-volt furnace thermostat will not work.

Never hook up household current, 120 Volts, to the millivolt

system. It is not recommended to hook up any more than

two switches to the insert (for example a rocker switch and a

wall thermostat). Additional switches may affect the system

resistance and increase the chance of the burner not ignit-

ing. Follow the instructions included with the thermostat or

remote control for wiring.

The thermostat, remote control, and rocker switch will turn

the burner on and off independently. Be sure to set the rocker

switch to the “OFF” position when using the thermostat or

remote control and set the thermostat or remote control to

the lowest temperature when you wish to use the rocker

switch only, otherwise one may override the other. If a re-

mote thermostat is to be used with the insert, do not place

the receiver under the firebox.

Millivolt and System Checks

Check

Test

To

Test

Connect

Meter

Leads to

Terminals

Thermostat

Connects

Meter

Reading

Should Be

A

Complete

System

 & 

Closed

100 MV

or More

B

Thermopile

Output

1 & 

Open

Greater

Than

5 MV

C

System

Resistance

1 & 

Closed

80 Ohms

Table 4

Figure 19

Thermopile

Pilot Hood

Pilot Tube

Spark Electrode

Terminal Snap Switch

Wire (Black SS1)

Spark Electrode Wire

(Black) connect to

Piezo Igniter

Burner Orifice

Thermopile Wire (Brown)

Connect to Terminals 1 & 2

On Gas Valve

On/Off Switch Wire

(Black) 001 Connect

Terminal 1 Gas Valve

Inlet Pressure

Tap

Gas Valve

Valve Snap Switch

Wire (Black) SS2

Inlet Elbow

Piezo Igniter

On/Off Switch Wire (Black) 002 - Connect Terminal 3 Gas Valve

Off/On/Pilot

Manifold

Pressure Tap

Flame Adjustment

On/Off

Switch

Thermostat

Wire

(White) TH2

Thermostat

Wire

(Red) TH1

OPTIONAL

Thermostat

Vent Safety Snap

Switch

50 60 70 80 90

50

60 70 80

90

Terminal 2

TP

Terminal 3

TH

TH

TP

TH

Terminal 1

TH/TP

Valve Terminals

m

illivolt

w

iring

d

iagram

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Advertising