LG B-VENT GAS GC3 User Manual

Page 18

Advertising
background image

18

To remove the front door open the side doors, release the

front door latches on either side and rotate the top of the

glass door forward and down until it stops. Once it is all

the way open, lift it slightly, move it to the left and pull it

away from the insert. Place door on a nonabrasive surface

being careful not to damage door or glass. When cooled the

exterior glass may be cleaned with a clean, soft cloth and

windex. For cleaning white condensation from the interior

glass use KEL KEM gas fireplace glass cleaner available

from your insert dealer. Use of caustic or abrasive cleaners

may damage glass.

NOTE: BE CAREFUL NOT TO SPRAY COMMERCIAL GLASS

CLEANER WITH AMMONIA ON GASKET AREA OF DOOR.

AMMONIA WILL DISSOLVE GASKET GLUE.

NOTE: GOLD PLATED SURFACE MUST BE CLEANED WITH

GLASS CLEANER AND SOFT RAG BEFORE FIRING THE

FIRST TIME OR FINGER PRINTS AND STAINS WILL REMAIN

PERMANENTLY. NEVER USE BRASS POLISH TO CLEAN

GOLD, THIS WILL REMOVE GOLD PLATING!

Front door glass replacement should be completed only by

a qualified technician.

g

lass

d

oor

C

leaning

a

nd

r

epair

Cleaning: Do not remove or clean the glass door when hot.

A gas door glass cleaner (available from your Lennox Hearth

Products dealer) or windex should be used with a soft cloth

to clean the glass. Do not use an abrasive cleaner.

Repair: If the glass is broken in the glass door, the entire

door (metal frame, gasket, and glass) should be replaced

as a unit. This replacement unit is available from your Len-

nox Hearth Products dealer. Do not use substitute parts or

materials.

Caution: Do not operate this insert with broken glass.

b

lower

r

emoval

Unplug the power supply cord from the electrical outlet prior

to removing the blower. The fan can be accessed through the

back wall of the firebox.

Caution: Label all wires prior to

disconnection when servicing controls. Wiring errors can

cause improper and dangerous operation. Verify proper

operation after servicing. See the fan-wiring diagram below

for reference. Remove the glass door, log set, and brick pan-

els. All of these items are fragile so handle them with care.

Remove the two allen-head screws at the left and right front

of the air control panel and lift the panel out. Next, remove

the nine allen-head screws around the outside of the panel

fastened to the back wall of the firebox. Rotate the top of

this panel toward the front, remove the two wires connected

to the fan, and then lift the panel with the fan attached out

of the firebox. To reinstall the fan, repeat these steps in the

reverse order.

e

leCtriCal

requirements

This gas insert operates without an outside power source,

however the fan/blower requires a 120 Volt electrical service

outlet. The blower must be electrically grounded in accor-

dance with local codes. In the absence of local grounding

codes, the National Electrical Code ANSI/ NFPA 70 - latest

edition. The blower is equipped with a three pronged (ground-

ing) plug for your protection against electrical shock hazard

and should only be plugged into a properly grounded three

prong receptacle. DO NOT CUT OR REMOVE THE GROUND-

ING PRONG FROM THE PLUG FOR ANY REASON!

• See Millivolt Control Schematic (Figure 19) for information

on thermostat and On/ Off switch.

• See Blower Wiring Diagram (Figure 1) for information on

the wiring and electrical requirements for the blower.

Figure 1

Snap Switch Connection

Wire (Black)

Pan Snap Switch

Snap Switch

Connection

Wire (White)

Speed Control Connection

Speed control Connection Wire (Black)

Blower

Main Power Cord (Black)

Main Power Cord Wire (White)

Main Power Cord Wire (Black)

Ground Wire (Green)

Speed Control ConnectionWire (White)

Speed Control Connection Wire (Black)

Speed Control

Connection Wire

(White)

Speed Control

Wire (Red)

Fan Speed Control

Speed Control

Wire (Red)

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

b

lower

w

iring

d

iagram

Advertising